caretaker 6-port valve

A new one-piece gear cartridge also makes the valve easier than ever to service. Perform a temperature risetest to determine where to set the bypass valve (see Figure 7). The pump can be run through out the day at low RPMs, allowing water rotation through the filtration system. Insert test plug in each stub-up. Installation Tip: Turn collar upside down and use as a tool to press ring into place. (5.1 cm) from the outer edge on steps and benches. Body housing must be primed heavily before gluing. If the wall return line can also recieve water pressure from the pump, install a check valve between the Caretaker valve and wall returns to prevent water from back flowing into the valve. Make line trench depth sufficient to cover all pipes with 6 (15 cm) of soil. Install all lines with a minimum of 6 (15.2 cm) cover or in accordance with local codes. Discharge pipes should extend 24 below the freeze zone before turning toward the pool. For variable speed pumps, see page 12.Heaters: To compensate for heater system pressure drops, plumb heaters in a bypass line before the water valve, even if the heater has an internal bypass. Developed in 1972, Caretaker is the original in-floor pool and spa cleaning system. Refer to exploded parts diagram for part references. Refer to the manufacturers instructions of the filter for proper cleaning instructions. The HydroMax shifting mechanism maximizes the time of full cleaning pressure to each zone. Mark the cleaning radius around each stake to verify cleaning coverage (Figure 2). Run the in-floor system without cleaning heads installed for 24 hours to ensure the lines are clean. Improper installation and/or operation will void the warranty. Verify proper water pressure at the gauge near the water valve. To determine the optimum cleaning time, run the system 24 hours a day to start.

Designed and tested in-house, Revolution passed the most rigorous tests Zodiac has ever conducted. However, the installer must follow the pipe size guidelines found on the certified pool plan which includes a minimum requirement of 2 PVC SCH40 for all floor inlets.Install the valve so that the body housing and outlet ports are above ground and the finished pool water level. Install the discharge lines from the valve in a stacked or flat configuration. Verify that the system is holding pressure (minimum of 35 psi), then relieve system pressure. Left justify heads next to sharp corners. Use compressor or blower to blow water from discharge lines. Dig trenches 8 in. Clean the pool filter whenever pressure increases 3 psi above normal clean-filter operating pressure. Remove the protective caps from the collars. Tighten the collar into the collar fitting, turning clockwise until the collar lip fits snugly against locking ring. Six hours a day is recommended. module Should You Consider Switching to Cost-Plus Pricing? Comment document.getElementById("comment").setAttribute("id","a7b45c1eb6cb6914a7304c4dfa1aa9dc");document.getElementById("afe6277d1c").setAttribute("id","comment"); Save my name, email, and website in this browser for the next time I comment. In the event no such state or local requirement exists, the installer or maintainer must be a professional with sufficient experience in pool equipment installation and maintenance so that all of the instructions in this manual can be followed exactly. For Vinyl Liner Pools:Pool liner must be in final position before installing collars and cleaning heads (see Figure 10). caretaker Fine tune your system by finding the minimum speed required to fully lift the heads. Run the system for a complete cycle to confirm that all cleaning banks operate and that each head advances during pop-up and retraction. Stake but do not plumb lines until walls are set; plumbing lines are fed under walls. Port 1 should always be the step or bench port, followed by the shallow bank, etc. 2 collars require 2 class 200 pipe (no reaming required) or 2 schedule 40 pipe (reaming required), 2.5 collars require 2.5 (6.35 cm) Schedule 40 Pipe (no reaming required), Position stub-up perpendicular (90) to the slope of the finished pool floor and secured to avoid movement durring gunite process. The company has a rich heritage of innovation excellence dating back more than 100 years and markets its product lines under the leading brand names of Zodiac, Polaris, Jandy, Nature2, Caretaker, Grand Effects and Cover-Pools. Ever. Installed to fit flush with your pool floor makes the system virtually invisible to the eye while continuously working to keep your pool clean and provide complete circulation of water, heat, and chemicals. Contact: 855.280.6465; caretakersystem.com, Pool & Spa News: Trends, news, products, design and business strategies for pool and spa professionals, Easy Sanitary Solutions Introduces Pool Drains, Reliant Pool Products Introduces Pump for Extreme Environments, New Customizable Grate Adds to RenoSys Line, Nidec Motor Corp.'s Aqua-Shield Line Features Moisture Resistance. Attach the Head Removal Tool (part #3-17-8) to the pool pole. Risers or stub-ups are glued into 2 (5.1 cm) Tees, 90-degree elbows, to stub-ups through the pool shell.Match the riser width to collar width. If the valve must be installed below water level, check valves or manual valves on the inlet and outlet ports are required to prevent flooding of the valve. Engineered for hassle-free maintenance, pool professionals will appreciate the ease with which Revolution can be serviced. The 6-Port Revolution valve is a hydraulically-driven, in-floor pool cleaning system from Caretaker. Use a blower assembly unit (blower, check valve, air/water supply, and connectors) to blow out debris that can gather in the plumbing during the construction process. Install the o-ring, lid and band clamp and torque clamp to approx. (20.3 cm) below excavated floor) and fill with concrete to form a thrust block to eliminate movement of the cleaning head. Caretaker Announces Revolution 6-Port Valve. Fluidra strives to deliver the perfect pool experience that enhances comfort, enjoyment, and peace of mind for pool owners. Designed with service technicians in mind, Revolution sets the new standard for in-floor cleaning valves with unsurpassed durability, increased efficiency and ease of servicing. Number the lines according to the design plan (see Figure 2). caretaker This ingenious valve offers effortless internal accessibility with a single band clamp that allows for quick access to the conveniently replaceable one-piece gear cassette. Use 90 elbows or tees at each head location. Carlsbad, CA 92010, Introducing Caretaker Revolution the most durable in-floor pool cleaning valve. Excavate a niche in pool wall, 6 x 24 (15.2 cm x 61.0 cm) down to the pool floor. Turn counter-clockwise (1/4 of a turn) to release head from collar. If the Caretaker cleaning system displays the following actions, adjustments may be necessary to restore performance. For Vinyl Liner Pools:Set collar fittings before clearing lines. Home CARETAKER CARETAKER REVOLUTION 6-Port Valve Installation Guide, REVOLUTION6-port valveInstallation and Maintenance Guide. Size the filter to exceed the flow requirements of the certified design. To learn more about Zodiac, please visit www.zodiac.com or call 800-822-7933. caretaker jandy

Its passed the most rigorous tests we have ever conducted; you can be certain these valves will stand the test of time.. ZODIAC is a registered trademark of Zodiac International, S.A.S.U., used under license. Top of stub-ups must be 6 (15.2 cm) above finished elevation. Use a sander/grinder to sand each stub-up smooth and level with the shell finish to ensure proper glue adhesion with collar setting. Insert Metal Combination Tool (part #3-17-7) into collar and rotate clockwise until collar is firmly seated. They glue directly into 2 schedule 40 fittings, dont require reaming and are ready for pressure testing. This information should be given to the owner/operator of this equipment. Failure to follow recommended installation methods and maintenance procedures could cause damage to pool equipment and/or personal injury, and may void the warranty. Caretaker2580 S Decker Lake Blvd, STE 300 West Valley City, UT 84119855.280.6465 toll-free | 801.906.6701 fax[emailprotected].comwww.caretakersystem.com. Attn: Customer Support

Prepare for cold weather by plumbing the valve so it can be winterized easily. on CARETAKER REVOLUTION 6-Port Valve Installation Guide, resideo Braukmann VT300 Installation Guide, resideo Braukmann VV300 Installation Guide, resideo Braukmann SV300 Installation Guide, Razor MX125 Charger Port Installation Guide, AJAX 8706 KeyPad Wireless Touch Keyboard User Manual, Meizhou Hongfeng Arts Crafts 266285 BJ 57IN Snowman With Snowflakes Instruction Manual, AJAX 7661 StreetSiren Wireless Outdoor Siren User Manual, AJAX 17938 12V PSU for Hub/Hub Plus/ReX Power Supply Unit User Manual, AJAX 10306 Transmitter Wired to Wireless Detector Converter User Manual, ZERFUN G8 Pro Wireless Microphone System User Manual, Airrex Infrared Heater AH-200/300/800 User Manual, 2017 Toyota Camry Hybrid LE Fuse Box Diagrams, 2017 Mitsubishi Lancer 4WD Fuse Box Diagrams, Mitsubishi Lancer Passenger and Engine Fuse Box Diagram, Mira Honesty ERD Bar Valve and Fittings User Manual. However, a high speed cleaning session will still be required to clean the floor of the pool. The Caretaker-certified pool plan indicates which cleaning heads will be plumbed together to form a bank. Verify that the excavated pool matches the Caretaker-certified pool plan. Ensure cassette assembly is removed. Electrical cost savings can be gained by using a variable speed pump. Perform a Hydrostatic pressure test by filling each line and the 6-Port valve with water. Run all feed lines to the top of the bond beam to facilitate easy valve hookup. Refer to the design plan to verify nozzle size. Improper installation and/or operation can create an unwanted electrical hazard which can cause serious injury, property damage, or death. Remove the cassette assembly. Turn clockwise (about 1/4 turn) to lock the head into position. Zodiac Caretaker Revolution 6-Port Hydraulic In-Floor Cleaning System, 2" Ports | WK000030, View Cart {{shoppingcart.totalQuantityDisplay}} Item(s), #WK000030 Zodiac Caretaker Revolution Hydraulic 6-Port Valve Complete with 2" Outlet Ports, #WK000030Zodiac Caretaker Revolution Hydraulic 6-Port Valve Complete with 2" Outlet Ports. If these instructions are not followed exactly, a fire or electric shock could result, causing property damage, personal injury, and/or death. Starting at the cleaning head farthest from the valve, remove test plug and flush the pipe, blocking and releasing pressure several times to ensure a clear line. Cut pipe stub-up flush with the pool floor. (Primer can be used on the stub-ups but not the collars. Your email address will not be published. Concrete or Vermiculite for Vinyl-Liner Ritz-Carlton Golf Resort, Naples Receives 2022 AI Dream Designs Honor, Check Out This Year's Dream Design Waterparks, These Family Aquatics Centers Take Dream Designs Recognition, See These Other Categories That Took Dream Designs Honors, The Cove at The Piazza Pool Awarded 2022 AI Dream Designs. Each head has a designated nozzle that has a precise cleaning radius (see Figure 1). The Caretaker system replaces unsightly vacuum hoses and other stand-alone pool cleaners so your pool area is uncluttered and always ready to be enjoyed. Refer to the design plan for the proper connections.CAUTION: Always plumb a check valve in each doubleported line. Replace band clamp and torque to approx.

When all connections are complete and it is clear that the system is holding pressure, backfill, tamp and level all trenches. Use heavy bodied PVC glue to secure the cleaning collars. Improper installation and/or operation will void the warranty. To minimize risk of severe injury or death the filters, pumps, and heaters should not be subjected to the piping pressurization test. For optimum cleaning efficiency, routinely clean the pool pump basket, skimmer and filter screens. Position o-ring in place and replace lid. The distribution system is designed to rotate from the shallow end to the deep end; pushing debris to the drain. All rights reserved. Verify all stub-ups are above the pool shell. Insert winterizing plugs into ports on the valve bottom or use 2-way valves on each line. Find a pool builder, retailer, or service professional in your area. Pool Equipment site managed by Itsopro Consulting | 2022 TC Pool Equipment Co. Not available online. Note: If 2 schedule 40 stub-ups are used, pipe reamer (part # 4-17-2) is required to allow the 2 collar to fit into the pipe.Hint: Save plumbing time by using 2.5 (Part # 5-9-150) or 2 (Part #WK000001) Prefabricated stub ups. WARNINGRead these instructions completely before starting the procedures. Featuring industry-exclusive technologies, Revolution is uniquely constructed using a heavy-duty valve plate with integrated ball bearings and extra thick gears supported by dual-reinforced shafts, which produces a strong hydraulic drive system capable of standing up to high pressures for years to come.

Use a check valve on the feed line in elevated spas to prevent spa water from flowing back into the pool.Follow the certified design plan to position and stake the cleaning head locations. 2580 S Decker Lake Blvd, STE 300 West Valley City, UT 84119855.280.6465 toll-free | 801.906.6701 fax[emailprotected]www.caretakersystem.com. (4.8 cm) lower than the floor level. For technical assistance, contact Caretaker for assembly instructions. Check the break, width, depth, and designated step/bench locations. Follow the design plan to install the lines in the correct order (See Figure 5). Open the valve and remove cassette assembly and packaging prior to gluing. Do not bury valve after installation.Install cleaning heads and nozzles according to the Design Plan.If pool includes an elevated spa, install a check valve on the line feeding the spa heads to avoid spa draining. Clear debris from all filters and pump basket. WARNINGWhen pressure testing a system with water, air is often trapped in the system during the filling process. Attach the Head Removal Tool (part number 3-17-8) to the pool pole. Clear lines and insert test plugs limiting water use as there is no solid pool bottom. Vinyl collars are not adjustable, stub-ups must be perpendicular to finished pool floor. Failure to follow warning notices and instructions may result in property damage, personal injury, or death. (see Figure 3). Place winterizing plugs into collars that are above water line to prevent runoff from filling the lines and refreezing. Installation of this equipment should be performed by a licensed pool contractor and should comply with all applicable local laws, ordinances, codes, and regulations. A Dozen Ways to Strengthen Your Remodeling Brand, Decoding the Framing Square for Rafter Layout, New Tool: Metabo HPT MultiVolt Cordless Compressor, A Deck Builder's Guide to 'Google My Business', JLC Rolls Out Deck and Railing Skills Workbook, Webinar: What You Need to Know About Decking. All other trademarks are the property of their respective owners. Press locking ring firmly into place in groove on collar fitting. Looking down on the valve, it rotates clockwise. WARNINGTo reduce the risk of electrical shock: Install all electrical equipment at least 5 feet (1.5 m) from inside wall of pool or spa. Disconnect power before servicing this equipment. Use glue on both.). Each Caretaker system is custom designed for the unique size and shape of your pool. We exist to create the perfect pool experience by designing innovative solutions that increase comfort, enjoyment, and peace of mind. Push collar firmly into pipe with a 1/4 turn. If all outlet ports on the valve are not needed, double-port the line by tying the unused port into an active port. WARNINGInstallation of this equipment should be performed by a licensed pool contractor and conform to the National Electrical Code (NEC) . Remove any cleaning heads located above the freeze line (step or bench heads). Caretaker design dimensions are from the finished pool, not excavation. If any dimensions have changed, a new plan must be drawn to ensure cleaning and warranty.Position the valve as close as possible to the swimming pool or water feature to reduce piping and improve performance. Lift straight up to release head from the removal tool. Trade Grade Series. The Caretaker cleaning heads are designed to operate at a specific gallonage and pressure. (7.6 cm) stagger when cutting pipes to provide enough clearance for the elbows. WARNINGThis product must be installed and serviced by authorized personnel, qualified in pool/spa installation. Install the nozzles into the cleaning head. The Caretaker system first revolutionized pool cleaning nearly 50 years ago, said Drechsel, Now, with this new Revolution that makes cleaning swifter and more streamlined for superior results, were doing it again.. Refer to instructions on Page 11. (20.3 cm) below excavation grade to accommodate setting of fittings. During gunite application, leave a 1 (2.5 cm) deep x 1 (2.5 cm) wide well around each stub-up. Then use an inside pipe cutter to cut it again 1 in. All applicable local installation codes and regulations must be followed. If a spa is included, it will require a dedicated line from the valve. (0.6 cm) edge around the ring perimeter. Before installing this product, read and follow all warning notices and instructions that accompany this product. App Store is a service mark of Apple Inc. Google Play is trademark of Google, Inc. All other trademarks referenced herein are the property of their respective owners. Every effort to remove trapped air must be taken.Pressure testing applies only to the plumbing and not to the pool equipment such as the filters, pumps, and heaters. NEW Jandy TruDose provides advanced technologies to properly maintain pool chemical levels. Cleaning times will vary according to application and environment. Pump: Choose an appropriate pump size and style to meet the GPM flow rate minimums specified on your certified pool plan. Excavate an area (12 in. When performing hydrostatic pressure tests or when testing for external leaks of the completed filtration and plumbing system, ensure that the maximum pressure the system is subjected to does not exceed the maximum working pressure of any of the components within the system. SAN DIEGO July, 8 2019 Caretaker, the original in-floor pool and spa self-cleaning system, is taking in-floor cleaning to new levels of efficiency with its latest innovation the Caretaker Revolution 6-Port Valve. caretaker polaris kit valve ring vac gould dust Perimeter heads have a 1 ft. (0.3 m) overlap. Lay out system so feed pipes enter the pool in the center of the wall closest to the pool equipment and valve. And, if the valve should ever have a problem, it remains open eliminating dead head and protecting the plumbing, pump and filter. Use 45 and sweep elbows to improve water flow. Apple and the Apple logo are trademarks of Apple Inc., registered in the U.S. and other countries. Ultra-durable valve plate with ball bearings, WK000030Caretaker 6 Port Valve, 2 Inch Outlet Ports Complete. Before initiating the system, open a discharge line before the valve and flush the pool pump and filtration system. Ensure collar is perpendicular with pool shell; you can rotate the 2-1/2 Ultraflex collar up to 10 to accommodate a crooked 2.5 stub-up. Snap tool into the head. Refer to the manufacturers instructions for the pumps, filters, and heaters for instructions regarding the maximum pressures the pool equipment can be subjected to.

Set head in collar; make sure the head is completely in the collar. Use a razor knife to cut liner inside the locking ring, leaving at least a in. Use a 3 in. To ensure complete cleaning and to qualify for the 99% cleaning guarantee, the pool builder must fax or email a Design Fact Sheet along with a scaled pool plan for FREE In-Floor DesignService prior to plumbing the pool.Email: [emailprotected]Fax: (801)-906-6701If the pool design or dimensions change during excavation, a new design plan must be drawn, or the cleaning guarantee will be void. T0073500 Rel-00042020 Caretaker In-Floor Systems, Braukmann VR300 Installation Instructions E1 Components Pilot valve Filter insert Manual ball valve E2 Installation E3 Commissioning Manufactured, Braukmann VV300 Installation Instructions E1 Components Pilot valve CX-PS Pilot valve CX-PR Filter insert Manual ball valve E2, Braukmann SV300 E1 Components Pilot valve Filter insert Manual ball valve Needle Valve E2 InstallationE3 Commissioning PB =, MX125 CHARGER PORT INSTALLATION PART # W15118260106 Required Tools: (Not included) A. Phillips screwdriver B. Flathead screwdriver C.. Reduce run times by 2 hours every 2 days until minimum cleaning time is determined. The Revolution 6-Port Valve from Caretaker In-Floor Pool Cleaning Systems is designed to be durable, efficient and easy to service. Should the system fail, this trapped air can propel debris at a high speed and cause injury. Pressure-test the system at a minimum of 35 psi for 24-48 hours or as local code requires. This is the most durable in-floor pool cleaning valve built. Turn on blower and water supply and direct the flow to one zone at a time. With Revolution, Caretaker also introduces the new QuickFlow Hydraulic Shifting System that provides the fastest shifting times tested, working even with low pump speeds, and maximizes full-pressure cleaning time with smoother zone shifting. (tap on the perimeter periodically to ensure equal tension). WARNINGFOR YOUR SAFETY This product must be installed and serviced by a contractor who is licensed and qualified in pool equipment by the jurisdiction in which the product will be installed where such state or local requirements exists. WARNINGTo reduce the risk of injury, do not allow children to handle this equipment unless they are closely supervised. The 6-port valve provides dependable and efficient in-floor cleaning by maximizing water flow through strategically placed cleaning heads to give your pool a robust and thorough cleaning. The cleaning head MUST be in the full down position before removal (see Figure 13). (30.5 cm) around head and 8 in. The valve can be placed near the other pool equipment for aesthetic purposes. 2020 Zodiac Pool Systems LLC. To maintain flow through the heads, run the system whenever the pump is on. Use heavy bodied PVC glue to connect the PVC pipe to the valve housing using glue manufacturers instructions.

Sitemap 26

caretaker 6-port valve