When the desired Backwash time appears in the display, press the SELECT button twice to return to the normal run (time of day) screen. Again look for a fast drain flow. Press and hold the SELECT button until the screen in Figure 26 is displayed. This is a reminder to use Morton MWSC Water Softener Cleanser three times a year. Use a floor drain, laundry tub, sump, standpipe, or other options (check your local codes). Step 4: Unit is ready for storage. THERE ARE NO WARRANTIES ON THE WATER SOFTENER BEYOND THOSE SPECIFICALLY DESCRIBED ABOVE. To set this monitor system: When this feature is ON, the water softener will operate at salt efficiencies of 4000 grains of hardness per pound of salt or higher (May recharge more often using smaller salt dosage but more regeneration water). 1. Thoroughly check the water softener for possible shipping damage and parts loss. When the desired Fast Rinse time appears in the display, press the SELECT button once to return to the normal run (time of day) screen. To change the length of the Backwash: Adjustable Fast RinseTo change the length of the Fast Rinse: CustomizingFeatures / Options(All Models). An obstructed flow indicates a plugged top distributor, backwash flow plug, or drain hose. NOTE: Be sure all 3 tabs of the clip go through the matching holes on the water softener valve inlet or outlet, and fully into the channel on the single bypass valve. NOTE: If the water softener was regenerating when power was lost, it will now finish the cycle. Open all faucets to drain all water from house pipesNOTE: Be sure not to drain water from the water. The efficiency rating is valid only at the stated salt dose. Make sure the bypass valve(s) is in the service (open) position. Then the words PRESENT TIME appear and 12:00 PM begins to flash. Manufactured and warranted by Water Channel Partners 1890 Woodlane Drive Woodbury, MN 55125, Protect your new water softener with Morton Clean and Protect or Morton Clean and Protect Plus Rust Defense Pellets.

30) Four months have elapsed on the systems timer since start-up or the last reset.

For example, assume your water is 20 gpg hard and contains 2 ppm iron. Avoid installing in direct sunlight. avoid salt bridging. Press the SELECT button once more to complete the initial programming.

This gap is needed to prevent the backflow of sewer water into the water softener. Do not allow the ofteners weight to rest on the inlet and outlet fittings or they may break. Call Toll Free 1-888-64 WATER (1-888-649-2837) or visit www.mortonwatersofteners.comWhen you call, please be prepared to provide the model and serial number, found on the rating decal, located on the rim below the salt lid hinges. Remove the top cover to expose the valve and observe cam and switch operation during valve rotation. This flushes any resin dust out. Plug the inlet and outlet with clean rags to keep dirt, bugs, etc. Light flashing, with the time of day shown in the display The salt monitor system indicates a low salt level and needs to be set. Step 3:Drain water from unit(do not dump the resin out). This water softener will reduce moderate amounts of this type of iron (see specifications). Leave the softener laying like his until you are ready to use it. Resin Tank, 8 x 35, Models M20 & M27, Reply. Install the softeners top cover and salt lid. When completed, full water conditioning capacity is restored. Set Water Hardness Number. If you have any questions or concerns when installing, operating, or maintaining your water softener, call our toll free number: 1-888-64 WATER(1-888-649-2837) or visit www.mortonwatersofteners.comWhen you call, please be prepared to provide the model and a serial number of your product, found on the rating decal, located on the rim below the salt lid hinges. Trace the water flow direction to be sure hardwater is to the inlet. Resin Tank, 9 x 35, Models M30, MC30 & M34, Brine Tank, Models with date code 20308 and below, Brine Tank, Models with date code 20309 and above, Rim, Models with date code 20308 and below, Rim, Models with date code 20309 and above, Faceplate Decal,Models M20, M27, M30 & MC30, Instruction Decal,Models M20, M27, M30 & MC30, Reply. Refer to warranty and elsewhere in this manual for further details on installation and maintenance, parts and service, user responsibility, and further restrictions, or limitations to the use of the product. ** Ferrous (clear water) iron is usually detected by taking a sample of water in a clear bottle or glass.

Use of any water softener additive rather than Morton MWSC will invalidate any extended warranty coverage. Be sure to provide a 1-1/2 minimum air gap to prevent possible sewer water backup. softener gpg hardness The one year warranty period, on all parts other than the salt storage tank and fiberglass mineral tank, can be extended to five (5) years from the date of purchase if you use Morton MWSC Water Softener Cleanser on your system. ): Manual Advance Regeneration CheckThis check verifies proper operation of the valve motor, brine tank fill, brine draw, regeneration flow rates, and other controller functions. It can negatively affect the taste of food, drinking water, and other beverages. Your demand water softener will automatically regenerate when it needs to, based on water usage. Then, press the SELECT button to set, and change to the flashing SET IME display. Lift the brine valve out of the brinewell. immediately when drawn from a faucet because it has oxidized before reaching the home. Be sure to keep fittings fully together, and pipes squared and straight. ), Distributor O-Ring Kit (includes Key Nos. Press the p UP button (a few times, if necessary) to display a flashing SOS. If this happens, you may want to initiate an immediate regeneration, as follows: Recharge TonightIf you do not want to start an immediate recharge, but would like to schedule an extra recharge at the next preset recharge time, do the following: The words RECHARGE TONIGHT flash in the display, and the softener will recharge at the next recharge time. Step 2:Perform the regeneration process Use the RECHARGE button to manually advance the valve into each cycle and check the correct witch operation. Press the SELECT button once again to display a flashing 25 and the word HARDNESS. Sediment is fine, foreign material particles suspended in water. Efficiency rated softeners have a rated salt efficiency of not less than 3,350 grains of total hardness exchange per pound of salt (based on sodium chloride) and shall not deliver more salt or be operated at a sustained maximum service flow rate greater than its listed rating.

Set Time of DayIf the words SET TIME do not show in the display, press the SELECT button until they do. Remove and discard (or recycle) all packing materials. see one bottle of Morton MWSC Water Softener Cleanser, as directed, every four months from the date of purchase of the water softener.

Sanitizing the SoftenerCare is taken at the factory to keep your unit clean and sanitary. Do not scratch, misshape, etc., surfaces of the nozzle & venturi. Step 12.

Be sure the brinewell cover is on.NOTE: In humid areas, it is best to keep the salt storage level lower, and to refill more often to avoid salt bridging. Close all cold water faucets and check for leaks at the plumbing connections that you made. ), you must drain all water from it to stop possible freeze damage. If this happens, you may want to initiate an immediate regeneration, as follows: The softener enters the filling cycle of regeneration right away.

NOTE: Press buttons and quickly release them to slowly advance the display. See the Set Water Hardness Number section. Founded in 2004, we are the leading developer of portable water softening and water deionization products. For this reason, sanitizing as follows issuggested* when installing. Close the inlet and outlet valve in a 3 valve bypass system, and open the bypass valve. Step 5: Connect the outlet of the softener to the point of application.Step 6: Your unit is ready for use. are other drain options. Alaundry tub, standpipe, etc. Do not lose the o-ring seal.

Adjustable BackwashIf your incoming water supply has higher sediments or clear water iron, a longer Backwash and/or Fast Rinse time may help in keeping the unit cleaner.

During installation, unsnap and remove the top cover, together with the salt lid, to expose the softener valve assembly. Some states do not allow limitations on how long an implied warranty lasts or exclusions or limitations of incidental or consequential damage, so the limitations and exclusions in this warranty may not apply to you. The water softener requires a minimum water flow of 3 gallons per minute at the inlet. Do not attempt to treat water over 120F. Slowly and gently, tip it over until the rim rests on the wood block with the inlet and outlet over the drain. This softener setting is shipped in the OFF position, which utilizes the maximum rated capacity while most often achieving maximum salt efficiencies. water softener pex installing warranty instructions installation Then, carefully push the broom handle straight down into the salt. If the letter appears, the switch is closed. Ferric (red water), and bacterial and organically bound irons are insoluble.

IronIron in water can cause stains on clothing and plumbing fixtures. 72) & 1 ea. Total iron is the sum of the contents. Using a container, add about three gallons of clean water into the salt storage tank. Undue stress from misaligned or unsupported plumbing may cause damage to the valve.Complete the inlet and outlet plumbing for the type of pipes you will be using. RECHARGE begins to flash as the softeners valve advances from the service to fill the position. Excessive sun heat may cause distortion or other damage to metallic parts. Add Morton System Saver II Pellets to the storage tank. This small component creates the suction to move brine from the brine tank, into the resin tank. on MORTIN Water Softener Instruction Manual, Programming the Water Softener (Models M20, M27, M30 & MC30), Programming the Water Softener (Model M34), ELRO Water Detector FW380111R Instruction Manual, LOREX W881AA Series 4K Wi-Fi Smart Deterrence Camera User Guide, LG HBS-FN7 Tone Free Bluetooth Stereo Earbuds User Manual, artika FM-ED-HD2GD LED Ceiling Light Instruction Manual, SAMSUNG ME21R7051SS Range Microwave Oven Instruction Manual, ThermoMart DTXG PID Temperature Controller Instruction Manual, ZERFUN G8 Pro Wireless Microphone System User Manual, Airrex Infrared Heater AH-200/300/800 User Manual, 2017 Toyota Camry Hybrid LE Fuse Box Diagrams, 2017 Mitsubishi Lancer 4WD Fuse Box Diagrams, Mitsubishi Lancer Passenger and Engine Fuse Box Diagram, Mira Honesty ERD Bar Valve and Fittings User Manual, Rated Softening Capacity (Grains @ Salt Dose). Customizing Features / OptionsQuestions? If daytime pressure is over 80 psi, nighttime pressure may exceed the maximum. This usually occurs in 15 to 30 minutes.

Until you have established a refilling routine, check the salt every two or three weeks. Resetting to Factory DefaultsTo reset the electronic controller to its factory default for all settings (time, hardness, etc. This iron is visible. Then, drain the water heater (following instructions for water heater) until water runs cold. Press and release (do not hold) the RECHARGE button. NOTE: Press buttons and quickly release them to slowly advance the display. Tip the bottom of the softener up a few inches and hold until all water has drained. Once in this display, press the SELECT button once and one of the two displays in Figure 22 is shown. Secure drain hose. 1. For the Standard model, use only one gallon of the solution with your unit and discard the rest per Sani-System instructions. Consider all of the following when selecting an installation location for the water softener. When completed (in about 2 hours), full water conditioning capacity is restored.NOTE: Avoid using hot water while the softener is regenerating, because the water heater will refill with bypass hard water. Step 1:Perform a back-flush. NOTE: If - - shows in the display, press the UP or DOWN button until the model code (see table n age 5) shows in the display. When the salt bridges, an empty space forms between the water and the salt. Install Valve Drain HoseNOTE: See valve drain options on pages 7 & 8. Protect the Water Softener from FreezingIf the softener is installed where it could freeze (summer cabin, lake home, etc. Press the SELECT button three times, so that Fr TIME appears in the display (See Figure 28). Secure valve drain hose in place. Overtightening may break the cap or housing. Recommended Salt: We recommend using Morton Clean and Protect Plus Rust Defense or clean and Protect Pellets in the familiar yellow bag. Place the brine valve back into the bottom of the brinewell and reinstall the brinewell cover. Variable Salt Dose: The salt dose is selected by the electronic controls at regeneration time based on the amount needed. Press and hold the SELECT button until one of the. However, it will operate at 4,000 grains per pound of salt or higher. European Directive 2002/96/EC requires all electrical and electronic equipment to be disposed of according to Waste Electrical and Electronic, Colloidal and inorganically bound iron (ferrous or ferric). Call Toll-Free 1-888-64 WATER (1-888-649-2837)or visit www.mortonwatersofteners.comWhen you call, please be prepared to provide the model and serial number,found on the rating decal, located on the rim below the salt lid hinges. Remove the softeners top cover, together with the alt lid. Call 1-888-64 WATER or visit www.mortonwatersofteners.com. When installing this unit in the State of California, you MUST turn his setting to the ON position, which may initiate more frequent charges. For best results use Morton Clean and Protect or Morton Clean and Protect Plus Rust Defense Pellets in your water softener. You can use either of these two options if draining water from theunit is required. Verify brine draw from the brine tank by shining a flashlight into the brinewell and observing a noticeable drop in the liquid level. This will prevent whipping during regenerations. Be sure the water softener is in the soft water (service) cycle (no water pressure at nozzle & venturi).

This water softener will not remove colloidal iron.In some instances, treatment may improve colloidal iron water. 5600sxt softener fleck valve programming button water efficiency max buttons enter controller master menu

If it should become plugged with sand, silt, dirt, etc., the water softener will not work, and hard water will result. EXTEND YOUR WARRANTY: Use MortonMWSC Water Softener CleanserThe factory warranty for your water softener is shown below.

55-59), Bypass Valve Assembly, 3/4, in- cluding 2 O-Rings (See Key No. All plumbing must be completed in accordance with national, state, and local plumbing codes. This may take 15 to 20 minutes. Run water until there is a steady flow from the opened faucets, with no air bubbles. If you wish to turn the Salt Efficiency feature ON ( icon will show in the display), follow the instructions on this page.

Step 6. Power Outage MemoryIf electrical power to the softener is interrupted, the time display is blank, but the electronic controller keeps the correct time for several hours. 25,500 @ 8.0 lbs. If a malfunction occurs, an error code appears in the display. Iron in water is measured in parts per million(ppm). Bypass valves allow you to turn off the water to the softener for maintenance if needed, but still have water in house pipes. The salt level scale, on the brinewell inside the tank, has numbers from 0 to 8 (See Fig. If a hard object is felt before the pencil mark is even with the top, its most likely a salt bridge. ** Capacity to reduce clear water iron is substantiated by laboratory test data. Shut off the electric or fuel supply to the water heater. If not already done, put a light coating of silicone grease on the single bypass valve o-rings. Press the SELECT button three times, to return to the normal run display (See Figure 37). If you want to change the recharge start time, press the.

Do not return the water softener to store. Lay a piece of 2-inch thick board near the floor rain (See Figure 45). If an incorrect model code is displayed, the softener will operate on incorrect configuration data. Electronic Control Board (PWA), Model M34, Brinewell Assembly (including salt level decal), Model M34, Brinewell Mounting Hardware Kit (includes Key Nos.

Close the faucet. WATER SOFTENER LIMITED WARRANTYWarrantor guarantees, to the original owner, that: If during such respective period, a part proves to be defective, Warrantor will ship a replacement part, directly to your home, without charge. The time of day that the automatic recharge cycle begins may be changed as follows: Step 4.

If an error code shows, first press the SELECT button to enter the diagnostic display. Hold the buttons down for fast advance.Step 2. NOTE: The electronic control display must show a steady time (not flashing).

If needed, use a small brush to remove iron or dirt. To have fully conditioned hot water immediately, wait until the initial recharge (Step 12) is over. The rated salt efficiency is measured by laboratory tests described in NSF/ANSI Standard 44. Up moves the display ahead; down sets the time back. If the water softener uses all theMorton Clean and ProtectPlus Rust Defense or Clean and Protect Pellets before you refill it, you will experience hard water. 13,700 @ 2.7 lbs. Do not locate the water softener where freezing temperatures occur. 72), Turbine & Support Assembly, including 2 O-Rings (See Key No. RECHARGE NOW will flash during the regeneration. Do not try to break the salt bridge y pounding on the outside of the salt tank. Electronic Control Board (PWA), Models M20, M27, M30 & MC30, Reply. To reset the timer, press any button on the control panel and CLEAn will disappear. box of iodized/non-iodized salt for the Standard model.- Two full 26 oz. If you wish to turn the Salt efficiency feature ON ( icon will show in the display), follow the instructions on this page. Colloidal iron water usually has a yellow appearance when drawn. Any other installed water conditioning equipment should be installed between the water inlet and water softener (See Figure 4 below). The error code will return if the problem was not corrected. Your email address will not be published.

Make sure the turbine assembly spins freely in the out port of the valve (See Figure 10). feature that complies with specific performance specifications intended to minimize the amount of regenerant brine and water used in their operation. remove the material from inside the tank. All other settings are maintained and never require resetting unless the change is desired. After the recharge has completed, fully open a cold water faucet, downstream from the softener, and allow 50 gallons of water to pass through the system. This information is retained by the computer from the first time electrical power is applied to the electronic controller. For soft water, nothing works harder. Install and tighten the cap by hand, while supporting the housing. Then, remove the nozzle & venturi disc, gasket, and flow plug(s). If local codes do not allow the use of a flexible drain hose, a rigid valve drain run must be used. Step 1:Turn off water and disconnect both inlet and outlethoses. To change the length of the Backwash: Low Salt Light / Clean ReminderWhen the water softener is connected to electrical power, the light on the control panel will operate as follows: This is a reminder to use Morton MWSC Water Softener Cleanser three times a year. Avoid elevating the hose more than 8 feet above the floor. Valve Drain RequirementsUsing the flexible drain hose (included), measure and cut to the length needed. However, regenerations may occur at the wrong time of day until you reset the clock to the correct time of day. *Let sit for 60 seconds max, turn water on full for 10 minutes to flush the Sani-System out of the unit.

of Key Nos. Be sure AM or PM is correct. DO NOT remove the material from inside the tank. Systems tested and certified by NSF Inter nation against NSF/ANSI Standard 44 for hardness reduction and efficiency, and certified to NSF/ANSI Standard 372. A nearby drain is needed to carry away regeneration discharge (drain) water. At times of greater than normal water use, such as when you have guests, you could run out of conditioned water before the next scheduled recharge. Turn the water on and rinse VERY SLOWfor the directed amount of time.Note: Stream of water should just clearthe side of the tank/the stream should be the size of a pencil.- Rinse for 12-15 minutes for the Standard Model.- Rinse for 24-30 minutes for the Double Standard Model.- Rinse for 50-60 minutes for the Park Model Water Softener.Step 7: Increase water flow to a full stream.- Rinse for 3-4 minutes for the Standard Model.- Rinse for 6-8 minutes for the Double Standard Model.- Rinse for 10-12 minutes for the Park Model Water Softener.Step 8: To verify the regeneration process is complete use the hardness test strips to insure the water at the OUTPUT of the softener is soft. Set them aside to prevent damage. Put the bypass valve(s) into service (soft water) position. Use a pressure-reducing valve if necessary (Adding a pressure-reducing valve may reduce the flow). NOTE: If your water supply contains iron, compensate for it by adding to the water hardness number. Press and hold the SELECT button until the screen in Figure 40 is displayed. Breaking a Salt BridgeSometimes, a hard crust or salt bridge forms in the brine tank. Adjustable BackwashIf your incoming water supply has higher sediments or clear water iron, a longer Backwash and/or Fast Rinse time may help in keeping the unit cleaner. Recharge the softener to reduce the water level in the tank. measure the distance from the floor to the rim of the water softener. Carefully remove the two large plastic clips (you will use them).

Back flush your Standard Softener every 3 months for 2-5 minutes, Double Standard Softener for 5-10 minutes, and 10-15 minutes for the Park Model Water Softener. Always make the initial checks, and the manual initiated diagnostics. Press the RECHARGE button to move the soften- ers valve into the fast inse position. Press and hold the SELECT button until one of the screens in Figure 21 is displayed. The water softener monitors electronic components and circuits for correct operation. Your Morton Water Softener has a High Efficiency feature with an ON or OFF setting. While in this diagnostic screen, the following information is available and may be beneficial for various reasons.

Check for leaks around clips at the softeners inlet and outlet. The screen in Figure 17 appears, with CLEAn flashing in the display when four months have elapsed on thesystems timer since start-upor the last reset. The current time of day will show in the display. Be sure AM or PM is correct. Recharge NowAt times of greater than normal water use, such as when you have guests, you could run out of conditioned water before the next scheduled recharge. Step 13. Press and hold the RECHARGE button until the words RECHARGE NOW flash on the display. 11,100 @ 2.2 lbs. Generally, these irons are removed from water by filtration. 28,100 @ 11.2 lbs. Set the present time, hardness, etc., as described on pages 13 & 14 (for Models M20, M27, M30 & MC30) or pages 16-18 (for Model M34). This softener setting is shipped in the OFF position, which utilizes the maximum rated capacity while most often achieving maximum salt efficiencies. Open salt lid, remove the brinewell cover, and pour about 3 oz. The foregoing warranties do not cover and Warrantor shall not be responsible for reimbursement for labor, transportation, removal, installation, or other expenses which may be incurred by Purchaser in connection with replacement or repair or return the product to Warrantor. Step 4. Purchase a compression fitting (1/4 NPT x 1/2 in. This is a good time for the recharge to start in most households because water is not in use. The water softener works on 24V DC electrical power, supplied by a direct plug-in power supply (included). Home MORTIN MORTIN Water Softener Instruction Manual, Water SoftenerModels M20, M27, M30, M34 & MC30How to install, operate and maintain your Demand Controlled Water Softener. softener water barista espresso recharging manual