reverse osmosis diagram pdf

If this is the only/last filter you are replacing continue to the Restarting the System section. 0000011618 00000 n

Do not tamper with the air valve on the lower side of the Water Storage Tank. Push hard enough on the tubing to make sure the Quick Connect has locked before moving on. All O-Rings, fittings, filter canisters, and Teflon tape wear out after a certain period of time. 705 0 obj <>stream To Cut TubingMake your cuts against a flat cutting surface with a razor blade, or use a handheld tube cutter. This prolongs the shelf life of the filters and avoids any possible odors or contamination from the air. Using this method it is okay to store filters for several years. Let the system refill with water (this takes 2-3 hours). 2. The lifetime of your components are subject to change with the quality of the water supplied. Remove the old filter from the holding clips and discard. bentex explanation blogmaygomes dol tonetastic

You have purchased the finest residential Reverse Osmosis Drinking Water System available for your home. 0000371144 00000 n 0000002461 00000 n Turn off the Cold Water Supply connected to the RO System, the Feed Water Adapter Valve, and the Tank Valve. Any cuts to your Tubing must be perfectly straight.NOTE!Improperly cut Tubing may leak water or fail to lock into Fittings.Wait until all elements of your RO System are in their final locations before cutting your Tubing. 0000010021 00000 n The Feed Water Adapter Valve controls all water coming into your RO System. You may have other rights depending on your state. Open the water supply to the RO System (use Cold Water Supply and Feed Water Adapter Valve) (Make sure the main water supply is also on). Use Blue Locking Clips to secure all 3 connection points as shown. 0000294399 00000 n NOTE!Make sure to remove any plugs before attempting to insert tubing. 0000024653 00000 n Position the Leak Stop Valve on the floor of the same cabinet (so any leaking water will make contact with the valve) beside the system and use the two screws to secure the Valve to the cabinet floor. The RO Faucet may be installed on any flat surface. It has been preset at 7-10 PSI. Take the plastic wrap off of the Compressed Textile then place the Textile inside the Leak Stop Valve as shown above. 0000292360 00000 n (If you smell bleach from your RO Faucet repeat steps 7-9). Locate the red Feed Water Adapter Valve connected to your Cold Water Supply.Turn Off System: Turn the red Feed Water Adapter Valve to point away from the Red Tubing connection (in the Closed position) to close the water supply to the system.Turn On System: Turn the red Feed Water Adapter Valve to point towards the Red Tubing connection (in the Open position) to open the water supply to the system. Let the water drip for 5 minutes. 0000096528 00000 n 0000260575 00000 n (Be sure to check for new leaks during the first 24 hours after restarting.). 0000335351 00000 n 0000371390 00000 n 0000017431 00000 n After unwrapping, place the new filters inside their correct housings. Let us walk you through these options; call us at 1-800-992-8876 or visit expresswater.comDoes this system soften water?Your RO System will soften water. Vacation ModeWhen you plan to not use your RO System for 2 weeks or more it should be Turned Off. 0000290878 00000 n 0000356661 00000 n 0000184332 00000 n 0000017319 00000 n Screw until tightened and the arm of the Elbow is facing upwards at an 11 OClock angle (use the above image for reference). Weve marked where the colored tubes will go with matching colored plugs in each fitting.We know life isnt always so simple though. 0000028781 00000 n 0000334770 00000 n Be sure to note which side is the front and which side is the back. Can I reuse discharge water?Never consume discharge water. Use your hands to screw each Filter Housing onto the RO System. RO UnitTop ComponentsInline Post Carbon Filter FLTIN01PKQRO Membrane Filter FLTMEME50 / FLTMEME100Bottom ComponentsFilter Housings PRTHSF10DB14Sediment Filter FLTSED0501GAC Filter FLTGAC0501Carbon Block Filter FLTCAR0501C. Your email address will not be published. We recommend emptying the Water Storage Tank four times (which can take 8-12 hours) to release any extra carbon before the water is safe to drink.How much water can the Water Storage Tank hold?The maximum capacity of the tank is 3.2 gallons. What is the operating pressure?The minimum PSI for the system is 40 and the maximum PSI is 80. If you reach 6 months or 1 year without noticing a change in taste you should still change your filter at this point as they are no longer viable.Can I add additional filters to my current system?Yes, each system is fully upgradeable. Using the Feed Water Adapter ValveDuring installation leave your Feed Water Adapter Valve in the CLOSED position until System Startup.

Release Tubing/PlugsIf there is a Locking Clip on the Collet it must be removed before the Tubing can be released. Use a proper 1/2 drill bit (depending on your sink/counter material) to make a hole for your RO Faucet. D! Test your water pressure occasionally to make sure the system is performing. NOTE!If your Cold Water Valve is too old or weak to connect to directly Option A you can connect at the top of the line where the faucet connects Option B (if applicable, some sinks do not have this connection point). Screw until tightened and the arm of the Elbow is facing downward. NOTE! 0000291361 00000 n 0000012572 00000 n 0000017468 00000 n 0000294330 00000 n Open the Water Storage Tank box and unscrew the Tank Stand from the threaded stem at the top of the Tank. Your water pressure, incoming water quality, and water temperature will affect your RO Systems discharge rate.Why does it take so long to fill up the tank?The purification process takes some time on its own. 0000026487 00000 n Under the sink install Plastic Washer, Lock Washer, and Hex Nut (see image on next page) onto the Threaded Faucet Stem. 0000421704 00000 n 0000147523 00000 n Make sure it is tight, but do not over-tighten.

Turn the Tank Valve to the Open position. 0000025919 00000 n Use the Filter Housing Wrench to open the Filter Housings, then remove and dispose of ONLY the following filter cartridges: Sediment Filter, GAC Filter, Carbon Block Filter, and RO Membrane. 0000017952 00000 n 0000003435 00000 n If so, will it affect the efficiency of the RO System?Yes, the RO System can be installed in a basement. Please make sure your installation location has enough room for the RO System and Water Storage Tank. 0000022686 00000 n You can open the RO Faucet briefly to release any air trapped inside the system while its filling. 0000018339 00000 n Contact Express Water and we will help you arrange your upgrade.Why are there bubbles in the water?Bubbles in your water is a common issue, but they only affect the appearance of your water and pose no risk. 0000016092 00000 n For warranty questions, service, or help give us a call Monday Friday 10 am to 5 pm PST: 1-800-992-8876, Express Water Inc.12730 Raymer St, Unit 1, North Hollywood, CA 91605, Reverse Osmosis System Installation Manual Download [optimized]Reverse Osmosis System Installation Manual Download, Dryer Installation Manual - Download [optimized]Dryer Installation Manual - Download, WODER Trusted Water Filter GUIDLINES Maximum recommended flow rate: 0.8 GPM Estimated Life Expectancy: 10000 Gallons/ 3 years, IKEA MALM Installation Manual IKEA MALM Installation Manual - Download [optimized] IKEA MALM Installation Manual - Download, Rheem Tankless Water Heater User Manual - Download [optimized] Rheem Tankless Water Heater User Manual - Download. NOTE! Make sure you have shut down the RO System (Step 2 in the Prefilters section). After the 5th tank is filled you may drink the water. 0000292119 00000 n 0000001276 00000 n Mix 1 gallon of water with 2 tbsp of household bleach. Finish tightening each housing using the filter wrench. This includes the following: Replace the O-rings on the filter housings, membrane housing, fittings, and filter cartridges. Replace any connectors and filter housings with proper replacement parts. Sanitize your system as often as needed (how often changes with the profile of your areas incoming water). Always use proper replacement filter cartridges with the correct size and length replacements. Replace the Teflon Tape on all threaded connections and fittings. 0000013647 00000 n HV{kGJ!KR4BQspcIiH? Use your drill and an appropriate 1/4 inch (6.35mm) drill bit to drill a hole at your mark. 0000011083 00000 n 0000031465 00000 n Connect one end of the Red Tubing into the Feed Water Adapter Valve and connect the other end of the Red Tubing into the hole marked IN on the Leak Stop Valve. 0000370916 00000 n If your state law requires it or you prefer to we recommend using a professional licensed installer or plumber who meets the requirements of this system. However, if you notice a drop in water quality before the 6 months or 1-year mark this may mean that due to your water quality your filter has degraded. The system will release water when it is disassembled.). submerged gac

CAUTION!The water supply to the unit MUST be from the COLD WATER LINE. 0000021641 00000 n

0000363686 00000 n Secure the White Tubing into the Male Elbow Fitting. Wash out the RO Membrane Housing. Incoming WaterIncoming water pressure must be between 40 PSI and 80 PSI. 0000210184 00000 n 0000012520 00000 n Remove the Red Plug. 0000261811 00000 n Do not handle an unwrapped filterdirectly with your bare hands as this can cause early filter failure. 0000291288 00000 n 0000003006 00000 n 0000371463 00000 n Open the RO Faucet handle and drain the system completely (wait until water flow stops completely), then close the Faucet handle. Porcelain SinkA proper porcelain 1/2 drill bit is strongly recommended to prevent chipping if you are drilling on a porcelain sink. osmosis distillation vapour desalination tvc seawater Turn off the system before servicing or inspecting. 0000387599 00000 n If your system does include a Gauge we will install it now. Pull out the RO Membrane with a pair of pliers. 0000005819 00000 n 0000003130 00000 n ;tsu8(GFb6&- Flush the system by opening the RO Faucet handle until the stored water is completely emptied and the flow is reduced to a trickle (about 1-5 minutes).

0000003606 00000 n Open the incoming water to the system (Feed Water Adapter Valve) and let it run for 10 minutes. 90 0 obj <> endobj xref 90 111 0000000016 00000 n endstream endobj 674 0 obj <. 0000290417 00000 n Please refer to System Startup section for detailed instructions, ignore any additional sanitation steps therein. No part of this publication may be reproduced, distributed, or transmitted in any form or by any means, including photocopying, recording, or other electronic or mechanical methods, without the prior written permission of the publisher, except in the case of brief quotations embodied in critical reviews and certain other noncommercial uses permitted by copyright law. Do not overtighten. (|#%\+2iJ{Sqifd&%|z+6y'd$;'.n)xzYMGhQhy;5'OLC>)'FIo 9Qe)sM;J4=Z;lk[T""m7fa/Q0XhS-czFdM@hxnESOM/]vU"mIs"&wvEqx]Y Be careful not to damage your tubing as you unpack it. However, hard water does reduce the lifespan of your Filters.

Do not add bleach directly to the filter housing. As shown below, the Feed Water Adapter Valve can be used for 3/8 or 1/2 feed line plumbing. A to B Connect the RED Tubing to the Feed Water Adapter Valve (point A), then to the hole marked as IN on the Leak Stop Valve (point B).C to D Connect the WHITE Tubing to the hole marked as OUT on the Leak Stop Valve (point C), then to the Sediment Filter Housings Male Elbow Fitting (point D).E to F Connect the BLACK Tubing to the Flow Restrictor side indicated by the arrow on the Restrictor (point E), then to the Drain Saddle (point F).G to H Connect the YELLOW Tubing to the Inline Post Carbon Filters Stem Run Tee (point G), then to the Water Storage Tanks Tank Valve (point H).I to J Connect the BLUE Tubing to the Stem Elbow at the end of the Inline Post Carbon Filter (point I), then to your RO Faucet connection (point J). Check for leaks daily during the 1st week of use and periodically thereafter. NOTE!Not all RO Systems include a Pressure Gauge. (You may wish to insert the Compressed Textile after System Startup is complete in case of early monitored leaks). 0000357372 00000 n 4v guide watts Close the RO Faucet handle and allow the Tank to fill again. Lower water pressure means the tank will hold less water. Install the system in a location with adequate drainage.GeneralThis RO System unit is for climate-controlled indoor use only. 0000317531 00000 n Place the RO System in the bucket and unscrew the 3 Prefilter Housings using the Filter Housing Wrench. 0000134930 00000 n Does it stop filling automatically when filled? 0000259710 00000 n Home Osmosis Reverse Osmosis System Installation Manual, Reverse OsmosisOverall System Connections, Your drinking water is going to be healthier and taste better from now on, and nothing makes us happier. 0000006762 00000 n 0000021566 00000 n 0000290541 00000 n Attach TubingPush Tubing in straight and level with the Collet. You may need other changes to media for high levels of these substances.What PSI do I need? Tools RequiredBefore you begin please make sure you have all of the following tools ready to use: Box Cutter Phillips-Head Screwdriver Power Drill 1/4 Drill Bit (for Drain Saddle Valve) 1/2 Drill Bit (for RO Faucet) Adjustable Wrench, Your new Reverse Osmosis Water System should include the following items.If any item is missing please contact Express Water.Please take a few moments to check all the following components:Accessories and Connections, Leak Stop Valve ComponentsLeak Stop Valve3 Replacement Pads2 Mounting Screws.

Sitemap 1

reverse osmosis diagram pdf